Open 24/7, 365 days a yearMinneapolis & St. Paul, MNCommercial Only
(651) 395-3422

American Range repair in the Twin Cities

American Range commercial range, oven, griddle and fryer repair on site in the Twin Cities: pilots, burners, thermostats, ovens and safety valves.

(651) 395-3422
Quick answer

What fails most often on an American Range?

On American Range ranges and ovens the common failures are standing pilots that go out, clogged burner ports, weak thermocouples, oven safety valves and drifting thermostats. Griddle sections add thermostat and valve problems. Heavy build means frames last while valves and pilots wear.

About American Range equipment

American Range makes commercial gas ranges, ovens, griddles, broilers and fryers and is a common choice in restaurant kitchens that want a heavy range at a moderate price. In the Twin Cities that means independent restaurants, school and church kitchens, small hotels and cafes, and any operation buying a line of equipment for a new build-out, where a range, a griddle and a fryer arrive from the same maker at the same time.

The model number tells you the layout. A string like AR-4B-36RG describes a range with four open burners and a 36-inch raised-back griddle section, and further letters describe the oven or base. Knowing the layout before the visit tells us which valves, pilots and thermostats to bring. Our approach is the same as for any commercial range, with attention to the oven side as a commercial oven repair, and to the griddle section when the flat top is the problem. Imperial is the closest comparison.

American Range open-top ranges

Seen on this line: Pilot out, weak or sooted / Burner ports blocked by spills / Stiff or leaking front valves

American Range open-top ranges use cast-iron burners with a pilot per burner or a pilot shared along a rail, with a manual valve on the front. The common calls are burners that will not stay lit or light unevenly, pilots that are weak or dirty, ports clogged with spilled product, and valves that stick or leak at the stem. A range that gets scrubbed with water or a pressure hose pushes moisture into the valves and pilots, and corrosion follows. Cast grates, burner heads and pilot assemblies wear out and are replaced as parts. Gas valve and pilot adjustments are left to a technician.

American Range ovens

Equipment guide

Commercial Oven Repair

Seen on this line: Thermocouple and safety valve faults / Thermostat calibration drift / Door sag and heat loss

The oven on an American Range base is a standard thermostat-controlled gas oven with a pilot and a safety valve, and convection ovens are sold separately with a fan and door switch. The calls are the oven that will not light, takes too long to heat, runs hot or cold, or loses the pilot after a few minutes. Causes are a thermocouple that no longer produces enough millivolts, a safety valve that does not hold, a thermostat out of calibration, and doors that sag so heat escapes. We check the oven with a separate thermometer before we adjust anything.

American Range griddles and fryers

Seen on this line: Cold spots from burner or plate problems / Thermostat calibration / Fryer pilot and high-limit faults

Griddle sections and stand-alone griddles use burners under a steel plate with a thermostat or manual control per zone. Failures are cold spots from clogged burners or warped plates, thermostats that stop reading correctly, and grease build-up in the burner area. American Range fryers are tube-fired with a pilot, a thermostat and a high-limit, and share the usual pilot and thermostat issues of that design. When a griddle shows a cold band, a technician checks burner flame pattern and plate flatness before assuming the thermostat is at fault. Spilled grease around the valves is cleaned up first.

Finding the model and serial plate

The rating plate is typically on the inside of the front panel, the oven door frame or behind the kick panel, and gives model, serial number and gas type. Model strings such as AR-4B-36RG encode burner count, griddle width and type. Read the whole string to the technician, and say whether the gas is natural or propane.

Parts

American Range parts are available from the manufacturer and from foodservice parts distributors. Pilots, thermocouples, valves and thermostats are common designs. Parts are matched by model, serial number and gas type, and burner and top castings are model-specific. Availability varies with model age, and we confirm the part number against the plate before anything is ordered.

Manufacturer warranty

If this equipment is still under the manufacturer's warranty, it should usually go through the manufacturer's authorized service network first. We are an independent company and not the manufacturer.

See also

American Range repair questions

What does the model string on our range tell us?

It encodes the layout: number of open burners, griddle width and style, and the oven or base type. It lets the technician plan parts before arriving, so read the full string off the plate when you call, including the letters after the griddle size.

Why does the pilot keep blowing out when the oven door slams?

A weak pilot flame, a draft from a sagging door or a pilot orifice partly clogged. A technician cleans the orifice, checks the thermocouple and sets the pilot to a stable blue flame. Check that the oven door closes square and is not left slamming shut during service.

Is it okay to pressure wash the range?

No. Water in the valves and pilot assemblies causes corrosion and stuck valves. Use degreaser, scrapers and wipe-downs, and keep water away from the controls. Let the range cool before cleaning, and pull the grates and burner caps to wash them separately.

Why is one side of the griddle cold?

A clogged burner or warped plate is the usual cause. A burner that is not lighting along its whole length shows as a cold zone, and a warped plate leaves a gap above the flame. Measure the plate with a surface thermometer first.

Can we mix natural gas and propane parts?

No. Orifices and valves are gas-specific. A range converted from one gas to another needs the correct conversion kit and a technician, because the orifices, pilot and regulator all change. Never swap parts between fuels to save time.

Call with the model and what it is doing

You hear the earliest opening on the phone. After the diagnosis you get a written price to approve before any repair starts.

(651) 395-3422
Call (651) 395-3422