Open 24/7, 365 days a yearMinneapolis & St. Paul, MNCommercial Only
(651) 395-3422

Charbroiler and salamander repair in Minneapolis and St. Paul

On-site repair for charbroilers, salamanders and cheesemelters: radiants, clogged burners, infrared elements, pilots, valves and lift mechanisms.

(651) 395-3422
Quick answer

Why is my charbroiler heating unevenly or losing heat?

Uneven heat on a charbroiler usually comes from burners clogged with grease and carbon, cracked or collapsed radiants or lava rock, or a gas supply and air mixture that are off. Salamanders and cheesemelters lose heat from failed infrared burners or a stuck lift. The burners are cleaned and tested before parts are replaced.

About charbroiler repair

Charbroilers, salamanders and cheesemelters are the high-heat finishing equipment on a line. A charbroiler cooks from below through radiants, ceramic or metal plates, or lava rock; a salamander or cheesemelter finishes from above with infrared burners. Because the heat sits right next to dripping grease and fat, the failures are different from a griddle or range: burners clog, radiants crack and fat fires leave carbon on everything. A broiler that looked fine last month can lose a third of its grate to clogged ports before anyone notices the steaks coming off cold.

We repair this equipment on site, at the business. Gas valves, pilots and any electrical work are technician work. We also service the exhaust hood and fan over a charbroiler (see hood and ventilation service), but a grease fire in or under one needs the suppression system and the fire department, and we do not service suppression systems. Gas odor at the broiler means leave and phone the utility or 911 from outside. When the line is back up, we can look at the burners and valves.

Kinds of charbroilers we repair

  • Radiant charbroiler

    Metal or ceramic radiants sit over the burner and spread heat evenly to the grates. Cracked or collapsed radiants leave cold bands and send grease straight onto the burner.

  • Lava rock charbroiler

    Pumice or lava rock replaces radiants. The rock loads with grease and breaks down over time, which cuts heat and adds flare-ups.

  • Infrared or ceramic-burner broiler

    Ceramic tiles glow at high temperature and cook by radiation. A cracked tile or a plugged mixing venturi gives a dead area.

  • Salamander or overhead broiler

    Mounted on a range or wall shelf, with infrared burners above the product. Many have a lift or rack mechanism whose springs and cables wear and drop the rack.

  • Cheesemelter

    A lighter-duty overhead broiler used for melting and finishing. It has the same infrared burners but runs cooler, so a failed burner is easier to miss.

  • Electric broiler

    Calrod-style or quartz elements and a contactor replace the gas burners. Elements burn out and terminal connections overheat.

Complaint, cause, correction

What the charbroiler is doing, why, and the repair
ComplaintLikely causeCorrection
Cold bands or dead sections across the grateBurner ports clogged with grease and carbon, a collapsed radiant that sits on the burner, or a burner that has not been lighting evenly from its crossover.Remove radiants and grates, clean the burners and ports, replace cracked radiants and check each burner lights through its crossover.
Flare-ups and fat firesGrease reaching hot burners because radiants are missing, broken or too widely spaced, or a drip tray that is full or misaligned.Replace missing or cracked radiants, clean the drip path and empty the tray. Heavy fire damage to the unit should be inspected before it is used again.
Burner flame is yellow and sooty or lifts from the portsA dirty air shutter, a partly plugged orifice or incorrect gas pressure. Heavy grease vapor can also coat the mixing tube and restrict air.Clean the air shutter and mixing tube, check the orifice and verify manifold pressure against the rating plate.
Burner will not light or pilot will not stay litA dirty pilot, a weak thermocouple, a pilot blown out by a drafty hood or a failed safety valve.Clean the pilot and orifice, test thermocouple output and replace the thermocouple or valve that fails. Pilot and valve work is technician work.
Salamander rack drops or will not hold its heightA worn spring, a frayed lift cable or a stripped adjuster on the rack or lift mechanism. A bent guide rail also makes it bind.Replace the spring or cable, straighten or replace the guide and adjust the rack stops.
Infrared burner glows in patches or not at allA cracked ceramic tile, a plugged venturi or a burner receiving poor gas-air mix. Overheating cracks ceramic burners over time.Inspect tiles, clean the venturi and replace the burner assembly if tiles are cracked.
Heat comes and goes across a busy serviceLow gas pressure at the appliance under load, a regulator that is sticking or a long run of undersized supply.Measure pressure at the appliance with all connected equipment running. The utility side of the meter and building gas piping are outside our scope, but a regulator at the appliance can be tested.
Electric broiler does not heat or heats in zonesA burned element, a failed contactor or a loose terminal. Grease can leak onto an element and burn the connection.Meter each element and the contactor and replace the failed part. Terminals showing heat damage are replaced, not tightened.

Check these before you call

  • Confirm the gas shutoff is open and that the broiler or salamander has not been pushed off its connector.
  • With the unit cold, look at the radiants or lava rock for cracks, gaps or heavy grease loading and note where they are.
  • Empty the drip pan and wipe out the grease path under the grate. Grease reaching a burner is both a heat problem and a fire risk.
  • On a salamander, check that the rack sits in its guides and the lift moves freely with the unit cold.
  • Check the breaker on electric units and the breaker feeding controls on gas models.
  • A gas smell from a charbroiler pilot or valve train is a call to the utility, made from outdoors. Do not relight pilots.

Stop at gas valves, 208, 240 or 480 volt wiring, sealed refrigerant circuits, steam under pressure and anything live. Those are a call.

While it is down

When a charbroiler is down, a griddle or a heavy pan on a range can cook many items, though char marks and flavor will differ. A salamander out of service means finishing in a hot oven or under a different broiler, and cheese dishes may need a convection oven instead. Report how much of the broiler is affected, how long the pilot stays lit and whether the grate area is dead or only cool. Take photos of the radiants and burners if you can. Do not try to cook over a burner that is flaring from missing radiants, and keep the area around the broiler clean of grease.

Upkeep that prevents the calls

Repair or replace

A charbroiler takes the harshest abuse on the line, so its parts are built to be replaced: radiants, burners, grates, valves and pilots. Repair makes sense on a unit with a solid frame and burner trays. Replacement is the better call when the burner trays are burned through, when the cabinet is rusted, or when a fire has damaged the valves and wiring. A salamander whose lift and burners are both failing may also be cheaper to replace. Our repair or replace guide explains how to weigh that, and a written estimate lets you compare.

Brands we repair

See also

Where we repair charbroilers

Every city we serve, by county

More cooking equipment repair

Charbroiler repair questions

What do radiants do on a charbroiler?

Radiants sit between the burner and the grate. They absorb burner heat and re-radiate it evenly across the grate, and they catch grease so it vaporizes instead of dripping onto the flame. Cracked radiants cause cold bands and flare-ups.

Why does my charbroiler flare up more than it used to?

More grease is probably reaching hot surfaces. Missing or cracked radiants, a clogged drip path or a full tray are the usual causes. Fix those before the next heavy service. A fire in or under the unit needs the suppression system, not a repair call.

Can I cook on a charbroiler that has a cold section?

You can, but food in that zone will cook slowly and unevenly. The cold section usually means a clogged burner or collapsed radiant. Keep the unit clean and have the burner inspected before it gets worse.

Why does the salamander rack keep dropping?

The spring or cable that holds the rack up is worn, or the stops that set its height have slipped. A dropped rack can drag food into the burner area. Replace the spring and cable as a set and adjust the stops.

Do cheesemelters fail the same way as charbroilers?

Mostly their failures are in the infrared burners, the pilot and the gas valve, not in grease loading. They run cooler and are mounted above the product, so a weak burner shows as slow melt time rather than flare-ups.

Is yellow flame normal on a charbroiler?

No. A yellow, sooty flame means poor air mixing, often from a clogged air shutter or mixing tube, and it deposits carbon on the grate and food. A technician cleans and adjusts the burner and checks gas pressure.

Call with the model and what it is doing

You hear the earliest opening on the phone. After the diagnosis you get a written price to approve before any repair starts.

(651) 395-3422
Call (651) 395-3422