Open 24/7, 365 days a yearMinneapolis & St. Paul, MNCommercial Only
(651) 395-3422

True refrigerator and freezer repair in the Twin Cities

On-site repair of True reach-in, undercounter, prep and glass-door refrigeration in Minneapolis, St. Paul and the surrounding metro. Diagnosis first.

(651) 395-3422
Quick answer

What fails most often on True refrigerators?

On True cabinets the usual failures are a dirty or blocked condenser coil, a worn door gasket, a failed evaporator or condenser fan motor, and a drain or condensate problem. Because many current True models run R290 hydrocarbon refrigerant, any sealed-system work needs a technician who handles flammable refrigerant correctly.

About True equipment

True Manufacturing builds reach-in, undercounter, prep and glass-door refrigeration in O'Fallon, Missouri, and has since 1945. Walk into almost any Twin Cities restaurant, bar, school kitchen or convenience store and a True cabinet is somewhere on the line. That volume matters for repair: a T-49, a TUC undercounter or a TSSU sandwich unit is a known layout, so reach-in cooler repair on a True usually starts from a familiar cabinet rather than a puzzle.

What sets True apart is the way the cabinet is built. Most uprights carry a self-contained, top-mounted condensing unit, stainless interior and exterior, and thick foam-in-place insulation. Many current models are charged with R290 hydrocarbon, shown by an HC at the end of the model number. That is a small charge of a flammable refrigerant, so recovery, leak checks and brazing follow different rules than an older R-134a or R-404A box. The same applies to a True commercial freezer with the HC suffix.

True reach-in and undercounter refrigerators

Seen on this line: Condenser coil packed with grease and lint / Torn or flattened door gasket / Evaporator fan motor slow or seized / Frozen or clogged condensate drain

The T-series uprights and TUC undercounters mostly fail for airflow reasons. The condenser coil sits under a lint and grease mat in busy kitchens, and a coil that cannot breathe pushes head pressure up, so the compressor runs long and the box drifts warm in the afternoon. After that come door gaskets that tear at the hinge side, evaporator fan motors that seize or turn slowly, and a drain line that freezes or clogs so water collects in the cabinet floor. On undercounters the front-breathing coil is the first thing to check. Door closers that no longer pull the door fully shut also let warm air in and frost the coil.

True reach-in freezers

Seen on this line: Open defrost heater or termination thermostat / Evaporator iced over / Door frame heater not working

A True freezer asks more of its defrost system than a cooler does. The failures we are called for are a defrost heater or termination thermostat that has opened, which lets frost build until the evaporator is a block of ice, and a defrost timer or control that no longer starts a cycle. A glazed evaporator then restricts airflow and the cabinet warms from the top. Door heaters and the heated frame around the opening matter as well, because a dead one lets the gasket freeze to the cabinet and tear when someone pulls the door.

True sandwich, salad and pizza prep tables

Equipment guide

Prep Table Repair

Seen on this line: Cold rail warm while the base is cold / Pan rail overfilled or lid left open / Worn drawer slides or lid hinges

TSSU and TPP prep tables have two temperature problems in one cabinet: the refrigerated base and the cold rail on top. The base fails like any other True cabinet, but the rail is cooled by its own air path, and a rail that runs warm usually means blocked airflow behind the pans, a lid left up, or a fan that has slowed. Overloaded pans and a rail packed above the fill line are common. Drawer rollers and lid hinges also wear out in heavy lines. A True prep table also carries a drain for the rail and a drain for the base, and a pan that sits crooked or a missing divider changes where cold air goes. Wear parts include the lid hinge, the cutting board rail and the drawer rollers on pizza prep units.

True glass-door merchandisers

Seen on this line: Door not closing on its own / Glass sweating or fogging / LED lighting out

GDM merchandisers are built for display, so LED lighting, glass seals and the condensate evaporator matter. The failures we see are a door that no longer self-closes, sweating on the glass when a gasket or door heater has failed, LED drivers that go dark, and condensate that overflows when the evaporator pan or its heater is not working. Because they sit in public view, a warm GDM is noticed quickly. Because a GDM is a merchandiser, product is stacked to the glass and shelves are loaded tight, which blocks the evaporator return. A cabinet loaded to the back wall warms even with a healthy compressor, so loading pattern is part of the diagnosis.

Finding the model and serial plate

On most True cabinets the serial and model plate is inside the box, on the interior wall near the top or on the ceiling, and sometimes behind the lower kick plate on undercounters. Read the full model including any HC suffix, the serial number, the refrigerant listed, and the voltage and amperage. The HC tells the technician whether the circuit holds R290 before anyone opens the cabinet.

Parts

True parts are sold under True's own part numbers, and gaskets, fan motors and controls are specific to the cabinet series. Generic fan motors and gaskets exist, but a replacement has to match fit and, on an R290 model, be rated for use with a flammable refrigerant. Lead time depends on the part and the supplier; some parts ship from the factory, others come through distributors.

Manufacturer warranty

If this equipment is still under the manufacturer's warranty, it should usually go through the manufacturer's authorized service network first. We are an independent company and not the manufacturer.

See also

True repair questions

What does the HC at the end of a True model number mean?

HC stands for hydrocarbon. It means the cabinet is charged with R290 propane refrigerant. The charge is small, but the refrigerant is flammable, so repairs that open the sealed system are done with the right recovery tools and no ignition sources.

Why does my True cooler run constantly but not get cold?

Start with the condenser coil. A coil clogged with grease or lint raises head pressure and the compressor cannot reject heat. Other causes are a stuck evaporator fan, a frosted coil from a failed defrost, or a door that is not sealing.

Can I replace a True door gasket myself?

On many True doors the gasket is a snap-in or screw-retained part, so a swap is possible. The risk is ordering the wrong profile or pulling the door frame out of square. If the door still leaks after replacement, a hinge or closer is usually the cause.

Do True freezers need a defrost heater replaced often?

Not often, but when a heater or termination thermostat opens the freezer warms in stages, not all at once. Frost builds on the coil, airflow drops and the cabinet temperature climbs. Replacing the part is cheap compared with the product lost.

Why is there water inside my True undercounter?

A blocked or frozen drain is the usual cause, followed by a condensate pan or evaporator tray that is not heated or not level. Look for ice at the drain port in a freezer. In a cooler, check the drain tube for slime or debris.

Call with the model and what it is doing

You hear the earliest opening on the phone. After the diagnosis you get a written price to approve before any repair starts.

(651) 395-3422
Call (651) 395-3422