Open 24/7, 365 days a yearMinneapolis & St. Paul, MNCommercial Only
(651) 395-3422

Commercial equipment repair guides

These guides are written for the person standing in front of the equipment. Troubleshooting guides start with what you can check safely and end with when to stop and call. The others cover the decisions around repair: cost, replacement, maintenance and inspection.

(651) 395-3422

None of them replaces a diagnosis on site, and none asks you to open a gas valve, a refrigerant circuit or live wiring.

Troubleshooting 9

  • Walk-in cooler not cooling: the order to check things

    Most walk-in coolers that stop cooling have a power or control problem, a dirty or blocked condenser, an iced-over evaporator coil, a failed fan motor, or a lost refrigerant charge. Staff can safely check the breaker, door seal and airflow. Anything inside the refrigeration circuit needs a technician.

  • Ice machine not making ice: what to check and in what order

    The usual causes are a closed water supply or clogged inlet screen, scale on the evaporator, a dirty condenser or blocked airflow, a bin control that thinks the bin is full, a failed water pump or harvest part, or a sealed-system fault. Staff can check supply, bin control and airflow safely.

  • Commercial fryer won't stay lit: causes and what to check

    A gas fryer that will not stay lit usually has a weak thermopile or thermocouple, a dirty pilot, a tripped high-limit, a failed ignition component, low gas pressure, or a drain valve or filter pan safety that is open. Staff can check the drain, pan and power. Gas valve and ignition work is for a technician.

  • Pizza oven not heating: causes, checks and when to call

    A pizza oven that will not heat usually has a gas ignition or safety valve fault, a failed element, contactor or thermostat, a tripped high-limit, or a power supply problem. Staff can check the breaker, setpoint and door. Gas valves, high-voltage wiring and burner work need a technician.

  • Commercial dishwasher not draining: causes and what to check

    Most commercial dishwashers that will not drain have a clogged scrap screen or strainer, a standpipe or overflow tube not seated, a blocked drain line or floor sink, or a failed drain valve, solenoid or pump. Staff can clear screens and check the floor drain. Plumbing and electrical faults need a technician.

  • Reach-in cooler running warm: causes and what to check

    A reach-in that runs warm usually has a dirty condenser coil, a failed door gasket, an iced evaporator from a defrost fault, a dead condenser or evaporator fan, a changed setpoint, or a weak compressor or low charge. Staff can clean the coil and check the gasket. Electrical and refrigerant faults need a technician.

  • Commercial oven pilot light problems: why it goes out and what to check

    A pilot that keeps going out usually points to a weak thermocouple or thermopile, a partly plugged pilot orifice, a draft or flue problem pulling the flame off the sensor, or a gas valve that will not hold open. The pilot assembly is cheap to test, but gas parts need a technician.

  • Walk-in freezer icing up: why it happens and how to stop it

    Ice builds when moisture gets in faster than the defrost cycle removes it. The usual causes are a failed defrost heater, timer or termination switch, a frozen or unheated drain line, a leaking door gasket, or a door left open. Where the ice forms points to the cause.

  • How to find the model number and data plate on commercial equipment

    Look for a metal or foil data plate. On refrigerators it is usually inside the cabinet or on the end wall. On ice machines and ovens it is on the back, side or inside the door or kickplate. The plate lists the model, serial number, voltage, phase, gas type and refrigerant.

Cost 1

  • What drives the cost of a commercial appliance repair

    A commercial repair bill is built from five things: the diagnosis, the class of part that failed, whether a sealed refrigerant system was opened, how hard the unit is to reach, and the age of the equipment. You approve a written price after diagnosis and before any repair starts.

Decisions 1

  • Repair or replace restaurant equipment: how to decide

    Weigh five things: the machine's age against its normal service life, what actually failed, whether parts are still available, what it costs to run, and what downtime costs your operation. A cheap fix to a sound machine usually wins. A major failure on old, inefficient equipment usually does not.

Maintenance 2

  • Commercial kitchen equipment maintenance checklist by frequency

    Daily tasks are cleaning and reading temperatures. Weekly tasks are gaskets, drains and filters. Monthly tasks are condenser coils, burners and pump screens. Quarterly tasks are the items a technician should test: refrigerant, controls, gas and electrical. Frequency depends on the equipment family and the manufacturer's manual.

  • Ice machine cleaning schedule: cleaning, sanitizing and water filtration

    Most manufacturers call for a full clean and sanitize at least every six months, and more often in hard water, high humidity or heavy use. Cleaning removes scale, sanitizing treats slime and microbes, and the two use different chemicals. Your model's manual sets the exact interval and the approved products.

Inspection and compliance 1

  • Health inspection refrigeration temperatures: what inspectors check

    Under the FDA Food Code, cold time/temperature control for safety food must be held at 41°F or colder, and hot food at 135°F or warmer. Cooked food must cool from 135°F to 70°F within two hours, then to 41°F within four more. Minnesota's Food Code, Minn. Rules chapter 4626, follows the same framework.

Call with the model and what it is doing

You hear the earliest opening on the phone. After the diagnosis you get a written price to approve before any repair starts.

(651) 395-3422
Call (651) 395-3422